Heater plus dehumidifier load
Can a heater and dehumidifier share one socket?
Check whether a heater, dehumidifier and air mover are too much for one socket or lead.
Safety boundary: this guide is for early planning only. It does not inspect hidden wiring, sign off an installation or replace a competent electrician.
Add the loads, not the labels
A 2 kW heater and a 650 W dehumidifier together are roughly 11.5 A at 230 V before fans or other equipment. That is already above an 80% warning point for a 13 A plug.
Run time changes the risk
Drying setups often run unattended for long periods. A setup that seems fine for a quick test can become unsuitable as a sustained load.
Split or reduce the setup
Move equipment to confirmed separate circuits, reduce wattage, use a different supply route, or ask an electrician or hire supplier before running the job.